Size SWA or T&E cable, MCB and 30 mA RCD for an outdoor hot tub, with burial and grouping correction factors to BS 7671.
Size SWA or T&E cable, MCB and RCD for an outdoor hot tub or spa, with grouping and burial correction factors to BS 7671.
Hot tubs are outdoor equipment, so the supply needs 30 mA RCD protection (Type A) and an IP65 double-pole isolator within sight of the tub. The outdoor or underground section must be SWA — twin and earth is not permitted outdoors. Buried cable runs are derated and must be at least 500 mm deep with warning tape.
The calculator applies ambient, grouping and insulation correction factors, then checks voltage drop. Hot tub installations are Part P notifiable.
Max Zs values, diversity factors, cable ratings, voltage drop — one printable page. Plus occasional emails with calculator updates and useful tips.